Results 1 - 20 de 29
Filter
1.
Rev. urug. cardiol ; 38(1): e405, 2023. ilus, tab
Article in Spanish | LILACS, UY-BNMED, BNUY | ID: biblio-1515549

ABSTRACT

La ablación de las venas pulmonares se ha convertido en un tratamiento clave para fibrilación auricular (FA). Sin embargo, pueden ocurrir recurrencias. La estrategia disponible para la ablación después de una recurrencia de FA es controvertida, compleja y desafiante, y la información es limitada. Mediante la presentación de una serie de casos se resumen y discuten elementos clave en la comprensión y tratamiento del paciente con FA recurrente sintomática después de un procedimiento inicial de ablación de venas pulmonares que requiere un nuevo procedimiento de ablación. En las últimas décadas se ha obtenido una mejor comprensión de los mecanismos fisiopatológicos implicados en la FA recurrente posterior a ablación de venas pulmonares, lo que permite identificar factores asociados, crear scores predictores e implementar técnicas de optimización o estrategias adicionales para mejorar la durabilidad y la eficacia del aislamiento de venas pulmonares. Debido a que la reconexión de venas pulmonares es un hallazgo típico durante los procedimientos repetidos, ésta debe ser considerada el objetivo principal de una nueva ablación. Las estrategias de ablación adicional (desencadenantes extrapulmonares o sustratos arritmogénicos) son controvertidas y requieren investigaciones futuras.


Pulmonary vein ablation has become a key treatment for atrial fibrillation (AF). However, recurrences can occur. The ideal strategy for ablation after AF recurrence is controversial, complex, and challenging, with limited data available. By presenting a series of cases, we summarize and discuss key elements in the understanding and treatment of patients with symptomatic recurrent AF after an initial pulmonary vein ablation procedure who are subjected to a new ablation procedure. In recent decades, there has been a better understanding of the pathophysiological mechanisms involved in recurrent AF after pulmonary vein ablation, making it possible to identify associated factors, create predictive scores and implement optimization techniques or additional strategies to improve the durability and efficacy of pulmonary veins isolation. Because pulmonary vein reconnection is a typical finding during repeat procedures, it should be considered the primary goal for a repeat ablation procedure. Additional ablation strategies (extrapulmonary triggers or arrhythmogenic substrates) are controversial and require further investigation.


A ablação das veias pulmonares tornou-se um tratamento chave para fibrilação atrial (FA). No entanto, podem ocorrer recorrências. A estratégia ideal para a ablação após uma recorrência da FA é controversa, complexa e desafiadora e existem dados limitados. Através da apresentação de uma série de casos resumimos e discutimos elementos chave no entendimento e tratamento do paciente com FA recorrente sintomática após um procedimento inicial de ablação de veias pulmonares, que são submetidos a um novo procedimento de ablação. Nas últimas décadas obteve-se uma melhor compressão dos mecanismos fisiopatológicos envolvidos na FA recorrente pós-ablação de veias pulmonares, isso permite identificar fatores associados, criar scores preditores, implementar técnicas de otimização ou estratégias adicionais para melhorar a durabilidade e eficácia do isolamento de veias pulmonares. Dado que a reconexão de veias pulmonares é um achado típico durante os procedimentos repetidos deve ser considerado o objetivo principal para uma nova ablação. As estratégias de ablação adicional (desencadeadores extrapulmonares ou substratos arritmogénicos) são controversas e requerem investigação futura.


Subject(s)
Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Catheter Ablation , Pulmonary Veins/physiopathology , Recurrence , Atrial Fibrillation/physiopathology
2.
J. Transcatheter Interv ; 31: eA20230010, 2023. ilus.; vid.
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1516849

ABSTRACT

A comunicação interatrial do tipo seio venoso superior geralmente acompanha-se de uma conexão venosa anômala de veia ou veias pulmonares superiores ou médias direitas, que drenam diretamente na veia cava superior ou, ainda, na junção cavoatrial. Relatamos o caso de uma paciente do sexo feminino, de 62 anos, com diagnóstico de comunicação interatrial do tipo seio venoso, com sobrecarga das câmaras direitas, para quem foi planejado o procedimento de oclusão percutânea do defeito por meio da realização prévia de tomografia cardiovascular e, sequencialmente, estudo anatômico tridimensional, com o software de acesso público 3D Slicer. Além disso, foi realizada a impressão do modelo em resina para inspeção e simulação de implante de um stent. A paciente foi tratada de maneira percutânea com um stent Chetham-Platinum coberto de 60mm de extensão, com oclusão total do defeito, ausência de shunts residuais e direcionamento do fluxo da veia pulmonar superior direita para o átrio esquerdo por comunicação posterior entre os átrios, condição essencial para a realização desse tipo de procedimento. O planejamento do procedimento de oclusão percutânea da comunicação interatrial do tipo seio venoso passa por avaliação criteriosa dos exames de imagem. A impressão de modelos virtuais ou físicos, derivados da angiotomografia cardíaca, é fundamental para estudo detalhado do defeito e das estruturas anatômicas associadas, minimizando a ocorrência de complicações.


A superior sinus venosus atrial septal defect is usually accompanied by an anomalous venous connection to a right superior or middle pulmonary vein or veins, draining directly into the superior vena cava or even into the cavoatrial junction. This is a case report of a 62-year-old female patient, diagnosed with a sinus venosus atrial septal defect, with overload of the right chambers, for whom a percutaneous occlusion procedure was planned, using a previous cardiovascular tomography and, sequentially, a three-dimensional anatomical study, with the publicly available software 3D Slicer. In addition, a resin model was printed for inspection and simulation of a stent implantation. The patient was treated percutaneously with a 60-mm covered Chetham-Platinum stent, with total occlusion of the defect, absence of residual shunts, and draining flow from the right superior pulmonary vein to the left atrium, through a posterior communication between the atria, a sine qua non prerequisite to perform this type of procedure. Planning of the percutaneous occlusion procedure of the sinus venosus atrial septal defect involves careful evaluation of imaging tests. The printing of virtual or physical models, derived from computed tomography angiography of the heart, is essential for a detailed study of the defect and associated anatomical structures, minimizing the occurrence of complications.

3.
Arq. bras. cardiol ; 120(5): e20220306, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1439333

ABSTRACT

Resumo Fundamento O ecocardiograma intracardíaco (EIC) permite visualizar estruturas cardíacas e reconhecer complicações durante a ablação da fibrilação atrial (AFA). Comparado ao ecocardiograma transesofágico (ETE), o EIC é menos sensível para detecção de trombo no apêndice atrial, porém requer mínima sedação e menos operadores, tornando-o atrativo num cenário de recursos restritos. Objetivo Comparar 13 casos de AFA utilizando EIC (grupo AFA-EIC) com 36 casos de AFA utilizando ETE (grupo AFA-ETE). Método Trata-se de corte prospectiva realizada em um único centro. O desfecho principal foi o tempo de procedimento. Desfechos secundários tempo de fluoroscopia, dose de radiação (mGy/cm2), complicações maiores e tempo de internação hospitalar em horas. O perfil clínico foi comparado pelo escore CHA2DS2-VASc. Um valor de p <0,05 foi considerado uma diferença estatisticamente significativa entre os grupos. Resultados A mediana do escore de CHA2DS2-VASc score foi 1 (0-3) no grupo AFA-EIC e 1 (0-4) no grupo AFA-ETE. O tempo total de procedimento foi de 129 ± 27 min grupo AFA-EIC e 189 ± 41 no AFA-ETE (p<0,001); o grupo AFA-EIC recebeu uma dose menor de radiação (mGy/cm2, 51296 ± 24790 vs. 75874 ± 24293; p=0,002), no entanto, o tempo de fluoroscopia em minutos mostrou-se semelhante (27,48 ± 9,79 vs. 26,4 ± 9,32; p=0,671). As medianas do tempo de hospitalização não se mostraram diferentes, 48 (36-72) horas (AFA-EIC) e 48 (48-66) horas (AFA-ETE) (p=0,27). Conclusão Nesta coorte, AFA-EIC foi relacionado a menores tempos de procedimento e menor exposição à radiação, sem aumentar o risco de complicações ou o tempo de internação hospitalar.


Abstract Background Intracardiac echocardiography (ICE) allows visualization of cardiac structures and recognition of complications during atrial fibrillation ablation (AFA). Compared to transesophageal echocardiography (TEE), ICE is less sensitive to detecting thrombus in the atrial appendage but requires minimal sedation and fewer operators, making it attractive in a resource-constrained setting. Objective To compare 13 cases of AFA using ICE (AFA-ICE group) with 36 cases of AFA using TEE (AFA-TEE group). Methods This is a single-center prospective cohort study. The main outcome was procedure time. Secondary outcomes: fluoroscopy time, radiation dose (mGy/cm2), major complications, and length of hospital stay in hours. The clinical profile was compared using the CHA2DS2-VASc score. A p-value <0.05 was considered a statistically significant difference between groups. Results The median CHA2DS2-VASc score was 1 (0-3) in the AFA-ICE group and 1 (0-4) in the AFA-TEE group. The total procedure time was 129 ± 27 min in the AFA-ICE group and 189 ± 41 min in the AFA-TEE group (p<0.001); the AFA-ICE group received a lower dose of radiation (mGy/cm2, 51296 ± 24790 vs. 75874 ± 24293; p=0.002), despite the similar fluoroscopy time (27.48 ± 9. 79 vs. 26.4 ± 9.32; p=0.671). The median length of hospital stay did not differ; 48 (36-72) hours (AFA-ICE) and 48 (48-66) hours (AFA-TEE) (p=0.27). Conclusions In this cohort, AFA-ICE was related to shorter procedure times and less exposure to radiation without increasing the risk of complications or the length of hospital stay.

4.
Arq. bras. cardiol ; 117(1): 100-105, July. 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1285226

ABSTRACT

Resumo Fundamento Na fibrilação atrial paroxística (FAP), o isolamento das veias pulmonares com criobalão (IVP-CB) tem eficácia semelhante à da ablação por radiofrequência (IVP-RF). Em procedimentos de reablação após IVP-RF, a reconexão das VPs é alta, ao passo que em pacientes com reablação após IVP-CB, as informações são escassas. Objetivo Determinar os locais de reconexão das VPs em pacientes que foram submetidos à reablação após IVP-CB inicial. Métodos Pacientes que foram submetidos a um procedimento de reablação de fibrilação atrial, após um IVP-CB inicial para FAP foram incluídos. O mapeamento eletroanatômico do AE foi utilizado. Um local de reconexão foi definido com a presença de uma voltagem de 0,3mV ou maior nas VPs e condução unidirecional ou bidirecional nas VPs durante o ritmo sinusal. Os locais de reconexão foram identificados por meio de corte paraesternal longitudinal e posteriormente ablacionados com radiofrequência. Resultados Dos 165 pacientes submetidos ao IVP inicial, 27 necessitaram reablações, dos quais 18 (66,6%) eram do sexo masculino, com média de idade de 55+12,3 anos. O tempo de recorrência foi de 8,9+6,4 meses. A reconexão das VPs foi encontrada em 21 (77,8%) pacientes. Houve um total de 132 lacunas de condução, seis por paciente, 3,6 por VP. Um número significativo de lacunas ocorreu na região ântero-superior da VP superior esquerda (VPSE) e nas regiões septal e inferior da VP superior direita (VPSD). Conclusões As VPs superiores apresentaram os locais de maior reconexão, principalmente na região anterior da VPSE e na região septal da VPSD. A razão por trás disso pode ser devido à maior espessura da parede atrial e à dificuldade em alcançar o contato de criobalão adequado.


Abstract Background In paroxysmal atrial fibrillation (PAF), pulmonary vein isolation using cryoballoon (CB-PVI) has similar efficacy as radiofrequency ablation (RF-PVI) has. In redo ablation procedures following RF-PVI, PV reconnection is high, whereas in patients with redo following CB-PVI, information is scarce. Objective To determine the sites of PV reconnection in patients who underwent redo ablation after initial CB-PVI. Methods Patients who underwent an AF redo procedure, following an initial CB-PVI for PAF were included. LA electroanatomic mapping was used. A reconnection site was defined as the presence of a voltage of 0.3mV or greater in the PV and unidirectional or bidirectional conduction in the PV during sinus rhythm. Reconnections sites were identified using a clock-face view description and were ablated with radiofrequency afterwards. Results Out of the 165 patients who underwent initial PVI, 27 required redo ablations, of which 18 (66.6%) were males, with a mean age of 55+12.3 years. The time of recurrence was 8.9+6.4 months. PV reconnection was found in 21 (77.8%) patients. There was a total of 132 conduction gaps, six per patient, 3.6 per PV. A significant number of gaps were in the anterosuperior region of the left superior PV (LSPV), and in the septal and inferior regions of the right superior PV (RSPV). Conclusions The upper PVs had the most reconnection sites, mostly at the anterior region of the LSPV and the septal region of the RSPV. The reason behind this may be due to greater atrial wall thickness, and difficulty in achieving adequate cryoballoon contact.


Subject(s)
Humans , Male , Adult , Aged , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Catheter Ablation , Cryosurgery , Recurrence , Treatment Outcome , Middle Aged
7.
Arq. bras. cardiol ; 115(3): 528-535, out. 2020. tab, graf
Article in Portuguese | LILACS, SES-SP | ID: biblio-1131326

ABSTRACT

Resumo Fundamento O isolamento elétrico das veias pulmonares é reconhecidamente base fundamental para o tratamento não farmacológico da fibrilação atrial (FA) e, portanto, tem sido recomendado como passo inicial na ablação de FA em todas as diretrizes. A técnica com balão de crioenergia, embora amplamente utilizada na América do Norte e Europa, ainda se encontra em fase inicial em muitos países em desenvolvimento, como o Brasil. Objetivo Avaliar o sucesso e a segurança da técnica de crioablação em nosso serviço, em pacientes com FA paroxística e persistente. Métodos Cento e oito pacientes consecutivos com FA sintomática e refratária ao tratamento farmacológico foram submetidos à crioablação para isolamento das veias pulmonares. Os pacientes foram separados em dois grupos, de acordo com a classificação convencional da FA paroxística (duração de até sete dias) e persistente (FA por mais de sete dias). Dados de recorrência e segurança do procedimento foram analisados respectivamente como desfechos primário e secundário. O nível de significância adotado foi de 5%. Resultados Cento e oito pacientes, com idade média de 58±13 anos, 84 do sexo masculino (77,8%), foram submetidos ao procedimento de crioablação de FA. Sessenta e cinco pacientes apresentavam FA paroxística (60,2%) e 43, FA persistente (39,2%). O tempo médio do procedimento foi de 96,5±29,3 minutos e o tempo médio de fluoroscopia foi de 29,6±11,1 minutos. Foram observadas cinco (4,6%) complicações, nenhuma fatal. Considerando a evolução após os 3 meses iniciais, foram observadas 21 recorrências (19,4%) em período de um ano de seguimento. As taxas de sobrevivência livre de recorrência nos grupos paroxístico e persistente foram de 89,2% e 67,4%, respectivamente. Conclusão A crioablação para isolamento elétrico das veias pulmonares é um método seguro e eficaz para tratamento da FA. Nossos resultados estão consoantes com demais estudos, que sugerem que a tecnologia pode ser utilizada como abordagem inicial, mesmo nos casos de FA persistente. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Background Electrical isolation of the pulmonary veins is recognized as the cornerstone of non-pharmacological treatment of Atrial Fibrillation (AF), and therefore, has been recommended as the first step in AF ablation according to all guidelines. Even though the cryoballoon technology is widely used in North America and Europe, this experience is still incipient in many developing countries such as Brazil. Objective To evaluate initial results regarding success and safety of the new technology in patients with persistent and paroxysmal AF. Methods One hundred and eight consecutive patients with symptomatic AF refractory to pharmacological treatment were submitted to cryoablation for isolation of the pulmonary veins. Patients were separated into two groups according to AF classification: persistent (AF for over one week); or paroxysmal (shorter episodes). Recurrence and procedural safety data were analyzed respectively as primary and secondary outcomes. The level of significance was 5%. Results One hundred and eight patients, with mean age 58±13 years, 84 males (77.8%), underwent cryoablation. Sixty-five patients had paroxysmal AF (60.2%) and 43 had persistent AF (39.2%). The mean time of the procedure was 96.5±29.3 minutes and the mean fluoroscopy time was 29.6±11.1 minutes. Five (4.6%) complications were observed, none fatal. Considering a blanking period of 3 months, 21 recurrences (19.4%) were observed in a one-year follow-up period. The recurrence-free survival rates of AF in the paroxysmal and persistent groups were 89.2% and 67.4%, respectively. Conclusion Cryoablation for electrical isolation of the pulmonary veins is a safe and effective method for the treatment of AF. Our results are consistent with other studies suggesting that this technology can be used as an initial technique even in cases of persistent AF.


Subject(s)
Humans , Male , Aged , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Catheter Ablation , Cryosurgery , Recurrence , Brazil , Treatment Outcome , Middle Aged
9.
Rev. urug. cardiol ; 35(1): 231-248, 2020. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1156860

ABSTRACT

Resumen: La ablación de la fibrilación auricular mediante el aislamiento de las venas pulmonares, es una estrategia ampliamente utilizada en la actualidad. La recurrencia posablación es un problema frecuente. Se han investigado varios predictores de recurrencia con el fin de optimizar la elección del paciente que más se beneficia del procedimiento. Actualmente la evidencia es controvertida, siendo necesarios más estudios al respecto.


Summary: The ablation of atrial fibrillation based on pulmonary veins isolation, is a widely used strategy nowadays. Post ablation recurrence is a frequent problem. Several recurrence predictors have been researched, with the purpose of choosing the patient that would benefit the most from this procedure. Current evidence is controversial and more research is needed.

10.
Arq. bras. cardiol ; 111(6): 824-830, Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-973806

ABSTRACT

Abstract Background: Pulmonary veins (PV) are often the trigger to atrial fibrillation (AF). Occasionally, left PVs converge on a common trunk (LCT) providing a simpler structure for catheter ablation. Objective: To compare the clinical characteristics and outcomes of ablation in paroxysmal atrial fibrillation (PAF) of patients with or without LCT. Methods: Case-control study of patients undergoing first-ever catheter ablation procedure for drug refractory PAF. The information was taken from patients' records by means of a digital collection instrument, and indexed to an online database (Syscardio(r)). Clinical characteristics and procedures were compared between patients with or without LCT (LCT x n-LCT), adopting a level of statistical significance of 5%. The primary endpoint associated with efficacy was lack of atrial arrhythmia over the follow-up time. Results: One hundred and seventy two patients with PAF were included in the study, 30 (17%) LCT and 142 (83%) n-LCT. The clinical characteristics, comorbidities, symptoms scale and risk scores did not differ between the groups. There was AF recurrence in 27% of PAF patients in the n-LCT group and only 10% of patients in the LCT group (OR: 3.4 p: 0.04) after a follow-up of 34 ± 17 months and 26 ± 15 months respectively. Conclusion: Patients with a LCT have a significantly lower recurrence rate when compared to patients without this structure. It is mandatory to report the results of AF catheter ablation as a PV anatomical variation function.


Resumo Fundamento: As veias pulmonares (VP) são frequentemente o local de origem da fibrilação atrial (FA). Ocasionalmente, as VPs esquerdas confluem em um tronco comum (TrCE) proporcionando uma estrutura mais simples para ablação por cateter. Objetivos: Tem-se como objetivo comparar as características clínicas e os resultados da ablação em pacientes portadores de FA paroxística (FAP) com ou sem TrCE. Metódos: Estudo do tipo caso-controle de pacientes submetidos ao primeiro procedimento de ablação por cateter para FAP refratária a drogas antiarrítmicas. As informações foram retiradas dos prontuários dos pacientes por meio de instrumento digital de coleta e indexadas a uma base de dados online (Syscardio(r)). As características clínicas e procedimentos foram comparados entre pacientes com e sem TrCE (TrCE x n-TrCE), sendo adotado nível de significância estatística de 5%. O desfecho primário associado à eficácia foi ausência de arritmia atrial ao longo do seguimento com único procedimento. Resultados: Cento e setenta e dois pacientes foram incluídos no estudo, 30 (17%) TrCE e 142 (83%) n-TrCE. As características clínicas, comorbidades, severidade de sintomas e escores de risco não apresentaram diferença estatística entre os grupos. Houve recorrência da FA em 27% dos pacientes do grupo não-TrCE e em apenas 10% dos pacientes do grupo TrCE (OR: 3,4 p: 0.04) após um seguimento de 34±17 e 26±15 meses respectivamente. Conclusão: Pacientes com TrCE apresentam significativamente menor taxa de recorrência quando comparados a pacientes sem esta estrutura. É imprescindível relatar os resultados da ablação por cateter de FA na vigência de variações anatômicas das VPs.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Pulmonary Veins/anatomy & histology , Atrial Fibrillation/surgery , Catheter Ablation/methods , Pulmonary Veins/diagnostic imaging , Recurrence , Tomography, X-Ray Computed , Case-Control Studies , Follow-Up Studies , Treatment Outcome , Kaplan-Meier Estimate
12.
Arq. bras. cardiol ; 110(5): 440-448, May 2018. tab, graf
Article in English | LILACS | ID: biblio-950162

ABSTRACT

Abstract Background: The influence of pulmonary vein (PV) anatomy on cryo kinetics during cryoballoon (CB) ablation is unclear. Objective: To investigate the relationship between PV anatomy and cryo kinetics during CB ablation for atrial fibrillation (AF). Methods: Sixty consecutive patients were enrolled. PV anatomy, including ostial diameters (long, short and corrected), ratio between short and long diameters, ostium shape (round, oval, triangular, and narrow), and drainage pattern (typical, with common trunk, common antrum, ostial branch and supernumerary PV) were evaluated on multi-detector computed tomography (MDCT) images pre-procedure. Cryo kinetics parameters [balloon freeze time from 0 to -30ºC (BFT), balloon nadir temperature (BNT) and balloon warming time from -30 to +15ºC (BWT)] were recorded during procedure. All p values are two-sided, with values of p < 0.05 considered to be statistically significant. Results: 606 times of freezing cycle were accomplished. Moderate negative correlation was documented between BNT and corrected PV diameter (r = -0.51, p < 0.001) when using 23-mm CBs, and mild negative correlation (r = - 0.32, p = 0.001) was found when using 28-mm CBs. Multivariate logistic regression analysis revealed that PV corrected ostial diameter (OR, 1.4; p = 0.004) predicted a BNT < -51ºC when using 23-mm CBs, while PV ostium oval shape (OR, 0.3; p = 0.033) and PV locations (left inferior PV: OR, 0.04; p = 0.005; right superior PV: OR, 4.3; p = 0.025) predicted BNT < -51ºC when using 28-mm CBs. Conclusions: MDCT can provide PV anatomy accurate evaluation prior CB ablation. PV anatomy is associated with cryo kinetics during ablation.


Resumo Fundamentos: A influência da anatomia da veia pulmonar (VP) na criocinética durante a ablação por criobalão (CB) não está clara. Objetivo: Investigar a relação entre a anatomia da VP e a criocinética durante a ablação com CB para fibrilação atrial (FA). Métodos: sessenta pacientes consecutivos foram matriculados. Foram avaliados em imagens de tomografia computadorizada multidetectora (TCMD) pré-procedimento a anatomia da VP, incluindo diâmetros dos óstios (longo, curto e corrigido), relação entre diâmetros curtos e longos, forma do óstio (redondo, oval, triangular e estreito) e padrão de drenagem (típico, com tronco comum, antro comum, ramo ostial e VP supranumerária). Os parâmetros criocinéticos [tempo de congelamento de balão de 0 a -30ºC (TCB), temperatura do nadir do balão (TNB) e tempo de aquecimento do balão de -30 a + 15ºC (TAB)] foram registrados durante o procedimento. Todos os valores de p são bicaudais, com valores de p < 0,05 considerados estatisticamente significativos. Resultados: o ciclo de congelamento foi realizado 606 vezes. Correlação negativa moderada foi documentada entre o TNB e o diâmetro VP corrigido (r = - 0,51, p < 0,001) ao usar CBs de 23 mm e correlação negativa leve (r = - 0,32, p = 0,001) foi encontrada ao usar 28- mm CBs. A análise de regressão logística multivariada revelou que o diâmetro corrigido do óstio da VP (OR, 1,4; p = 0,004) previu um TNB < -51ºC ao usar CB de 23 mm, enquanto a forma oval do óstio VP (OR, 0,3; p = 0,033) e as localizações da VP (VP inferior: OR, 0,04; p = 0,005; VP superior direito: OR, 4,3; p = 0,025) previram TNB < -51ºC ao usar CBs de 28 mm. Conclusões: A TCMD pode fornecer uma avaliação precisa da anatomia da VP antes da ablação por CB. A anatomia da VP está associada à criocinética durante a ablação.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Pulmonary Veins/anatomy & histology , Atrial Fibrillation/surgery , Catheter Ablation/methods , Cryosurgery/methods , Pulmonary Veins/physiopathology , Pulmonary Veins/diagnostic imaging , Atrial Fibrillation/diagnostic imaging , Kinetics , Tomography, X-Ray Computed , Prospective Studies , Treatment Outcome , Imaging, Three-Dimensional
14.
ABC., imagem cardiovasc ; 29(1): 25-27, jan.-mar.2016. ilus
Article in Portuguese | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-777620

ABSTRACT

A fibrilação atrial (FA) é a arritmia cardíaca sustentadamais frequente na prática clínica. Dados epidemiológicosdemonstram que a FA está associada a morbidadee a mortalidade expressivas, acarretando custosmédico-hospitalares elevados.1 O desalento geradopelo impacto modesto dos agentes antiarrítmicos nahistória natural da FA motivou o desenvolvimento demétodos não farmacológicos, visando o tratamentocurativo dessa arritmia. Nesse contexto, na últimadécada, a ablação por cateter com técnicas percutâneasevoluiu consideravelmente, consolidando-se comoopção terapêutica em pacientes selecionados com FA.2Métodos de imagem, tais como ecocardiografia intracardíacae mapeamento eletroanatômico, têm sido cada vez maisincorporados, com a finalidade de aumentar a eficiência ea segurança do método. A eficácia da ablação vem sendodiscutida nos últimos tempos buscando-se evidenciarfatores que contribuem para as taxas de recorrência daFA. A falha do procedimento é muitas vezes atribuídaà retomada da condução entre as veias pulmonares e oátrio esquerdo em razão da ablação incompleta dos focosectópicos.3...


Subject(s)
Humans , Male , Adult , Catheter Ablation/methods , Magnetic Resonance Spectroscopy/methods , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Pulmonary Veins , Arrhythmias, Cardiac , Echocardiography/methods , Treatment Outcome , Heart Atria
16.
Radiol. bras ; 46(6): 376-378, Nov-Dec/2013. graf
Article in English | LILACS | ID: lil-699245

ABSTRACT

Unilateral pulmonary vein atresia is a rare congenital condition. In addition to cardiac malformations or pulmonary hypertension, patients may present with recurrent pulmonary infections or hemoptysis in childhood or adolescence. The authors report a case where the typical findings of such condition were observed at computed tomography in an adult patient.

17.
Arq. bras. cardiol ; 101(6): 519-527, dez. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-701268

ABSTRACT

FUNDAMENTO: Índices de ondas P são marcadores interessantes para prever recorrências de fibrilação atrial (FA) pós ablação. OBJETIVO: Esse estudo avalia o valor dos índices de onda P para prever recorrências após isolamento da veia pulmonar (IVP) em pacientes com fibrilação atrial paroxística. MÉTODOS: Foram selecionados 198 pacientes (57 ± 8 anos, 150 homens) com FA paroxística sintomática refratária a medicamentos submetidos ao IVP em nosso hospital. Um eletrocardiograma de 12 derivações foi utilizado para medir a duração da onda P na derivação II, a força terminal de P (FTP) na derivação V1, o eixo e a dispersão da onda P. RESULTADOS: No acompanhamento de 9 ± 3 meses, as recorrências ocorreram em 60 (30,3%) pacientes. Os pacientes que apresentaram recorrência de FA tiveram maior duração média de onda P (122,9 ± 10,3 versus 104,3 ± 14,2 ms, p < 0,001), maior dispersão da onda P (40,7 ± 1,7 ms vs 36,6 ± 3,2 ms, p < 0,001). A duração da onda P > 125 ms apresenta 60% de sensibilidade, especificidade de 90%, valor preditivo positivo (VPP) de 72% e valor preditivo negativo (VPN) de 83,7%, enquanto a dispersão da onda P > 40 ms tem 78% de sensibilidade, 67% de especificidade, PPV 51% e VPN de 87,6%. 48/66 (72,7%) dos pacientes com FTP < -0,04 mm/segundo vs 12/132 (9%) com FTP > -0,04 mm/segundo tiveram recorrência de FA (p < 0,001). O eixo da onda P não diferiu entre os dois grupos. Na análise multivariada, os índices da onda P não foram independentes do tamanho do átrio esquerdo e da idade. CONCLUSÕES: A duração da onda P > 125 ms, a dispersão da onda P > 40 ms e FTP em V1 < -0,04 mm/sec são bons preditores clínicos das recorrências de FA pós IVP em pacientes com fibrilação atrial paroxística; contudo, eles não foram independentes do tamanho do átrio esquerdo e da idade.


BACKGROUND: P-wave indices are appealing markers for predicting atrial fibrillation (AF) recurrences post ablation. OBJECTIVE: This study evaluates the value of P wave indices to predict recurrences post pulmonary vein isolation (PVI) in patients with paroxysmal AF. METHODS: We selected 198 patients (57 ± 8 years, 150 males) with symptomatic drug-refractory paroxysmal AF undergoing PVI in our hospital. A 12-lead electrocardiogram was used to measure P wave duration in lead II, P wave terminal force (PWTF) in lead V1, P wave axis and dispersion. RESULTS: During a follow-up of 9 ± 3 months, recurrences occurred in 60 (30.3%) patients. The patients that had AF recurrence had longer mean P wave duration (122.9 ± 10.3 vs 104.3 ± 14.2 ms, p < 0.001), larger P wave dispersion (40.7 ± 1.7 ms vs 36.6 ± 3.2 ms, p < 0.001). P wave duration > 125 ms has 60% sensitivity, 90% specificity, positive predictive value (PPV) of 72% and negative predictive value (NPV) of 83.7%, whereas P wave dispersion > 40 ms has 78% sensitivity, 67% specificity, PPV of 51% and NPV of 87.6% 48/66 (72.7%) patients with PWTF < -0.04 mm/second vs12/132(9%) with PWTF > -0.04 mm/second showed recurrence of AF (p < 0.001). P wave axis was not different between two groups. On multivariate analysis, P wave indices were not independent from left atrial size and age. CONCLUSIONS: P wave duration > 125 ms, P wave dispersion > 40 ms and PWTF in V1 < -0.04 mm/sec are good clinical predictors of AF recurrences post PVI in patients with paroxysmal atrial fibrillation; however they were not independent from left atrial size and age.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Atrial Fibrillation/diagnosis , Electrocardiography/standards , Heart Atria/physiopathology , Pulmonary Veins/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Biomarkers/analysis , Catheter Ablation/methods , Heart Atria/surgery , Predictive Value of Tests , Pulmonary Veins/physiopathology , Recurrence , Sensitivity and Specificity
18.
Rev. méd. Paraná ; 71(1): 44-47, jan.-jun. 2013.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1352486

ABSTRACT

A drenagem anômala total de veias pulmonares (DATVP) é um defeito congênito cianótico em que todas as quatro veias pulmonares falham na sua conexão com o átrio esquerdo. Isto resulta na drenagem de todo o retorno venoso pulmonar para dentro da circulação venosa sistêmica. Relatar um caso de DATVP do subtipo infradiafragmática sem obstrução venosa pulmonar, diagnosticada em um recém-nascido (RN) que aos 21 dias de vida iniciou com cianose discreta, taquipnéia e cansaço as mamadas. As informações foram obtidas por meio de revisão do prontuário, entrevista com a responsável pelo paciente e revisão da literatura. O caso relatado e publicações citadas evidenciam a importância da reavaliação pediátrica criteriosa do RN no primeiro mês de vida para um diagnostico precoce de cardiopatias congênitas que podem se manifestar após a alta hospitalar do alojamento conjunto. A correção cirúrgica neste caso foi essencial para um melhor prognóstico do paciente


Total anomalous pulmonary venous connection (TAPVC) is a cyanotic congenital defect in which all four pulmonary veins fail in its connection with the left atrium. This results in the drainage of the entire pulmonary venous return into the systemic venous circulation. To report a case of TAPVC infradiaphragmatic subtype without pulmonary venous obstruction, diagnosed in a newborn (NB) that at 21 days of life began with mild cyanosis, tachypnea and fatigue feedings. Data were obtained by review of medical records, interview with the responsibility for the patient and review of the literature. The reported case and cited publications highlight the importance of careful reassessment of pediatric NB in the first month of life for early diagnosis of congenital heart disease that may manifest after discharge from the rooming-in. Surgical correction in this case was essential for a better prognosis

19.
Radiol. bras ; 43(6): 347-353, nov.-dez. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-571672

ABSTRACT

OBJETIVO: Demonstrar que a angiotomografia computadorizada com múltiplos detectores é um método efetivo e não invasivo para o diagnóstico de drenagem venosa pulmonar anômala. MATERIAIS E MÉTODOS: Estudo retrospectivo de 2.905 angiotomografias computadorizadas com múltiplos detectores cardíacas realizadas em nosso serviço no período de julho de 2003 a novembro de 2007. Destas, 393 foram destinadas para avaliar cardiopatias congênitas e as 2.512 restantes, para analisar as artérias coronárias. RESULTADOS: Foram encontrados 21 casos de drenagem venosa pulmonar anômala, sendo 7 (33,3 por cento) do tipo total e 14 (66,7 por cento) do tipo parcial. Das drenagens venosas pulmonares anômalas totais, três foram do tipo supracardíaco, três do tipo infracardíaco e uma do tipo cardíaco. CONCLUSÃO: A angiotomografia computadorizada com múltiplos detectores tem demonstrado fundamental importância no diagnóstico destas anomalias, principalmente por se tratar de método não invasivo capaz de analisar estruturas intra e extracardíacas e por permitir um estudo completo da anatomia torácica, contribuindo sobremaneira na conduta cirúrgica e, consequentemente, no prognóstico destes pacientes, especialmente por diagnosticar malformações não suspeitadas clinicamente.


OBJECTIVE: We aimed to determine if multidetector-row computed tomography angiography is an effective and non-invasive method for diagnosing anomalous pulmonary venous drainage. MATERIALS AND METHODS: We performed a retrospective review of 2,905 cases from July 2003 to November 2007 in which cardiac multidetector-row computed tomography angiography was used. Of the cases, 393 evaluated congenital cardiopathy, with the others (2,512) evaluating the coronary arteries. RESULTS: Anomalous pulmonary venous drainage was found in 21 cases, with 7 (33.3 percent) from total anomalous pulmonary venous drainage (3 supracardiac, 3 infracardiac and 1 cardiac), and 14 (66.7 percent) from partial anomalous pulmonary venous drainage. CONCLUSION: Multidetector-row computed tomography angiography can be useful for diagnosing the described anomalies because of its non-invasiveness, and its ability to evaluate intra- and extra-cardiac structures. The technique allows a thorough study of the thoracic anatomy and contributes to surgical conduct, consequently improving patient prognosis, in particular by allowing the diagnosis of clinically unsuspected malformations.


Subject(s)
Pulmonary Veins , Pulmonary Veins/physiopathology , Brazil , Drainage , Multidetector Computed Tomography , Retrospective Studies
20.
Rev. bras. cir. cardiovasc ; 25(4): 588-590, out.-dez. 2010. ilus
Article in Portuguese | LILACS | ID: lil-574757

ABSTRACT

Paciente de 13 anos de idade, sexo masculino, submetido à correção de estenose de túnel das veias pulmonares (ETVP) após cirurgia de Senning modificada realizada aos 5 meses. O quadro clínico era de congestão pulmonar e broncopneumonias de repetição e o ecocardiograma confirmou ETVP. Uma angioplastia com balão foi realizada previamente à correção cirúrgica com circulação extracorpórea. A placa de pericárdio bovino empregada para ampliação do átrio direito retraiu-se e calcificou, levando a ETVP. A placa foi removida e o átrio direito foi ampliado com um retalho de politetrafluoretileno. O ecocardiograma transesofágico intraoperatório demonstrou redução significativa da estenose.


A 13-year-old male was admitted to undergoing correction of a pulmonary venous baffle stenosis (PVBS) after a modified Senning procedure was performed by the age of five months. Recurrent Pulmonary congestion and pneumonia episodes were followed by echocardiography and cardiac catheterization that confirmed PVBS. Previous catheter balloon angioplasty was attempted, and a surgical revision was done under cardiopulmonary bypass. The bovine pericardial patch used for augmentation of the right atrium, retracted and calcified producing PVBS. Stenotic area was excised and enlargement was done with polytetrafluoroethylene membrane. Intraoperative transesophageal echocardiogram showed relief of stenosis.


Subject(s)
Humans , Animals , Male , Cattle , Cardiac Surgical Procedures/adverse effects , Heart Atria/surgery , Prostheses and Implants/adverse effects , Pulmonary Veno-Occlusive Disease/surgery , Vascular Surgical Procedures/methods , Membranes, Artificial , Pericardium/transplantation , Polytetrafluoroethylene , Pulmonary Veno-Occlusive Disease/etiology
SELECTION OF CITATIONS
SEARCH DETAIL